| Power
requirements |
240vac/1020
watts (optional 2020watts) |
|
| Control
type |
Custom
digital microprocessor |
|
| Control
range |
-20°C
to 150°C with 1° indication. (cooling required below ambient) |
|
| Control
stability |
±0.5ºC |
|
| Heat
up time |
20°
to 100° for 8 litres of Glycol at ambient 17°c is approx 45 minutes
with standard 1000 watt element.
|
|
| Pump
capacity |
10.5
litres/min. at zero head |
|
| Safety
features |
Low
level cut out, over temperature audible and visible alarm indication |
|
| Minimum
tank depth |
200mm |
|
| Overall
dimensions |
H310
x D190 x W125 |
|
| Weight |
3.4
kg |
|